Sababli tahlil:
1. Suyuqlikning emirilishi:
- yopishqoqlik buzilishi (kinematik yopishqoqlik)<40 cSt at 40°C).
- Air entrainment (foam stability >ASTM D892 uchun 5 minut).
2. Komponentni kiyish:
- Axial piston pump wear plate delamination (clearance >15µm).
- 5% FS dan yuqori bo'lgan mutanosib valf spyol spektori.
Tuzatish choralari:
- Yog 'holati monitoringi:
- Qo'shimcha deflamni aniqlash uchun elementar tahlil uchun yog 'namunasini (ICP {{{{{{{{}}}} AES).
- Agar zarrachalar soni ISO 18/16/13 dan oshsa, suyuqlik almashtiring.
- nasos ishlashini tekshirish:
- FREEFE® 754 yordamida Bosimning kompensatori javobini tekshiring<200ms.
- moslashtirilgan rotor / barrel anjumanlari bilan nasoslarni qayta tiklaydi.
- Valvil kalibrlash:
- Sinf porti orqali 2,0 ± 0,3 MPA ga 2,0 ± 0,3 MPA gacha
Operatsion ko'rsatmalar:
- Operatsiya paytida 50-70 darajadan ko'proq gidravlik neft haroratini saqlang.
- Yopiq - yog 'o'zgarishi uchun I-286